MSI Scantech pressure transmitters transducers
  MSI Scantech home pageemail msi scantechMSI Scantech products menu
pressure transducers transmitters

Series PA-9SEEC

Low Cost Pressure Transmitter

  • Brazed and welded 316L stainless steel
  • Interchangeable with Data Instruments EC Series
  • Accuracy ± 0.25%
  • Total Error Band +/- 1.0% (-10 to +80°C)
  • Voltage or Current Outputs
  • Gauge or Absolute reference pressure

The Series PA-9SEEC utilises the Keller 9SE piezoresistive capsule.
The diaphragm and body are 316 stainless steel as standard.
Available with 4 pin Hirschmann Mini-DIN 43650-C connector or 2 metres cable.
Choice of pressure port, either 1/8-27 NPT or G1/8 male.

Specification of the PA-9SEEC Low Cost Pressure Transmitter:

Ranges  
PR-9 gauge: 1, 2, 5, 10, 20, 50, 100, 200, bar
PA-9 absolute: 1, 2, 5, 10, 20, bar
Overload: 3 X range or 300 bar. May be operated up to 2X range.
Voltage Output (three wire): Signal: +0.5 to +4.4 Vdc (ratiometric to supply)
Supply: 5 ±0.25 Vdc@10mA typ.
Current Output (two wire) Signal: 4 to 20mA
Supply: 8-32 Vdc / Max. load 1K2
Zero Balance: ±1 mV
Supply: 5 Vdc @ 1 mA typ. Max. 20 Vdc
Accuracy: ±0.25% includes nonlinearity, hysteresis and repeatability
Stability: 0.25% per year
Temperature Effects  
Compensated: -10 to +80șC
Operating: -55 to +155șC*
*Special cable only
Total Band Error: ±0.5% (0 to +50șC)
±1.0% (-10 to +80șC)

 

Back to the MSI Scantech products index

MSI Scantech Products
The Centre, Reading Road, Eversley, Hampshire, RG27 0NB, United Kingdom
Telephone: +44 (0)118 973 0200 Facsimile +44 (0)118 932 8872



web site designed and maintained by adey.com